| Standard Incremental Scales and Masks |
 |
| Material: | - selected floatglass, scribed and broken
- planarity 10 µm/100 x 100 mm
- coefficient of expansion 9 µm/°C/m
- glass thickness for scale 2,0 +0/-0,2 mm
- glass thickness for mask 1,0 ±0,1 mm
- max. length of glass 3300 mm
- outbreaks on edges < 0,1 mm
|
| Graduation: | - sputtered chrome on glass
- transmission < 0,3% at 400 - 900 nm
- reflexion > 60% at 400 - 900 nm
- gratings 10 : 10 µm, 20 : 20 µm
- line width ratio 1 : 1
- max. line tolerance ±10%
- graduation accuracy < ±3 µm per 1000 mm
- parallelism graduation to glass edge < 0,3 mm per 1000 mm
- max. track length 3150 mm
|
| Acceptable defects in the graduation/reference mark area: | - pinholes < dia Ø 250 µm or several smaller defects whose total area does not exceed this
- dots < dia Ø 180 µm or several smaller defects whose total area does not exceed this
- defects visible to the naked eye on the illuminated table are not critical
- max. 3 defects per 1000 mm
- minimum distance between two defects 40 mm
|
| Acceptable defects in the surrounding area: | - dots < Ø 0,3 mm
- max. 6 defects per 1000 mm
|
| On request: | - other glass types
- other glass thicknesses
- other coatings
- sliding coat on mask
- other gratings
|
| | |
| MSD 10 Incremental Scale for HEDS 9200 Module |

|
| Material: | - selected floatglass, unpolished
- planarity 10 µm/100 x 100 mm
- coefficient of expansion 9 µm/°C/m
- width of glass 8 mm +0/-0,2 mm
- glass thickness 0,9 ±0,1 mm
|
| Graduation: | - line width ratio 1 : 1
- max. line tolerance ±10 %
- sputtered chrome
- transmission < 0,3 % at 400 - 900 nm
- reflexion > 60% at 400 - 900 nm
|
| Grating: | 100 : 100 µm |
| Accuracy: | 5 or 10 µm/m |
| Standard measuring length: (mm) | 100, 180, 260, 340, 420, 500, 740, 980, 1160 (other lengths on request)
|
| Scale on profile: | connection scale to aluminium profile with rubber cord |
| Power supply: | +5 V ±5%, max. 100 mA |
| Output: | square wave signals from built-in Subdiving Electronics times 1 |
| Connection possibilities: | directly to suitable NC or DRO |
| |